Description

Human Tecar HCR 1002 is a professional TECAR therapy device for physiotherapists, clinics and sports teams from the Italian manufacturer Unibell Srl. The device directs a 0,447 MHz radio frequency signal through an electrode directly into the body to activate tissue microcirculation and metabolism. The capacitive (CAP) mode is designed for soft tissues, the resistive (RES) mode for bones, tendons and scar tissue. Medpoint is the official representative of Human Tecar in Estonia.

0,447 MHzoperating frequency
300 WRES mode power
450 VACAP mode power
~ 7,5 kgportable

How HCR 1002 works

The HCR 1002 is, according to the manufacturer, an electromagnetic stimulator of microcirculation. The radiofrequency signal does not propagate in the air, but is transmitted to the tissues through direct contact. The signal sets in motion the charged particles (electrolytes) naturally present in the body. This increases the cells' need for oxygen and nutrients and thus also the blood flow in the treated area. The heat is generated in the tissues themselves, not applied from the outside.

Level 1 – Biostimulation

Acceleration of intracellular energy metabolism and analgesic effect through free nerve endings.

Level 2 – microhyperemia

Oxygenation of cells, acceleration of capillary blood flow, and internal heat from metabolism.

Level 3 – vasodilation

Vascular dilation, increased temperature of deep tissues, increased blood flow and lymphatic drainage.

Accurate dosing

The power can be changed in very small increments. The display shows power, voltage, current and tissue resistance during treatment.

Diagram of the Human Tecar HCR 1002 capacitive CAP mode: active electrode, neutral electrode and movement of charges in muscle tissue
Capacitive mode (CAP). An insulated high-impedance electrode moves charges in soft, water-rich tissues: muscle, fat, blood and lymph. The circuit is closed via a neutral electrode. Italian labels for the diagram: active electrode is the active electrode, return electrode neutral electrode, muscle tissue muscle tissue and electric charges electric charges. Source: Unibell, Human Tecar HCR 1002 training material.
Human Tecar HCR 1002 resistive RES mode diagram: energy is concentrated in bone and tendon tissue between the active and neutral electrodes
Resistive mode (RES). The uninsulated stainless steel electrode directs energy to tissues with higher resistance: bones, cartilage, large tendons, aponeuroses and scar tissue. Source: Unibell, Human Tecar HCR 1002 training material.

Who is it suitable for?

Physiotherapist and clinic

Acute and chronic muscle and joint disorders, conservative and post-operative rehabilitation.

Sports team

Recovery after heavy exertion, overuse injuries and muscle pain, and preparation for competitions.

Rehabilitation and Health Center

Maintaining mobility in the elderly, rehabilitation of the disabled, swelling and feeling of heavy legs.

Veterinary

According to the manufacturer, the technology is also used in the rehabilitation of horses and small animals.

Indications by manufacturer

  • Musculoskeletal injuries: muscle contractures, strains, acute and chronic tendonitis, sprains, synovitis, bursitis
  • Degenerative and inflammatory joint diseases (arthrosis, arthritis)
  • Neck and back pain, lumbago, arm pain, lumbar radiculopathy and sciatica
  • Delayed onset muscle soreness (DOMS) after eccentric loading and muscle relaxation
  • Swelling and lymphatic circulation disorders, feeling of heavy legs, scar tissue and tissue fibrosis

Mode and electrode selection

The therapist selects the mode and electrode based on the tissue and effect needed.

Tissue to be treated Mode Electrode Diameters
Muscle, fat, blood and lymph tissue (soft, water-rich tissues) POSTAL CODE capacitive High impedance insulated electrode: flat or curved thermodynamic Flat Ø 80/65/55/40/30 mm, curved Ø 65/55/40/30 mm
Edema, lymphatic circulation, drainage POSTAL CODE capacitive Curved lymphodynamic electrode Ø 55 / 40 mm
Bone, cartilage, large tendons, aponeuroses, scar and fibrous tissue ORS resistive Low impedance flat electrode made of stainless steel Ø 90/65/50/35 mm
Closing the circuit (in both modes) CAP / RES Neutral electrode: flat plate or cylindrical (patient holds in hand)
Two variants of resistive electrode and neutral electrode placement in knee joint treatment
Electrode placement in RES mode using the knee joint as an example. The relative placement of the active electrode and the neutral electrode directs the effect to either superficial or deep tissue. Source: Unibell, Human Tecar HCR 1002 training material.

When is which action necessary?

Treatment goal Effect When to use
Improving microcirculation Acceleration of blood flow at the capillary level, reduction of pain, faster absorption of bruises and fluid accumulations Severely inflamed tissue, immediate postoperative period (swelling and inflammation), pain conditions, edema and lymphatic insufficiency, acute phase muscle injury, drainage at the end of treatment
Increasing vasodilation Vasodilation, increased blood flow and temperature, nutrient supply and waste removal Chronic inflammation, post-injury muscle conditions, old and extensive swelling, muscle contractures, improvement of muscle tone and trophism, circulatory insufficiency, compression syndromes
Increasing the internal temperature Internal warming of tissues without external heat, intensive oxygenation, deep thermogenesis in poorly blood-supplied tissues Muscle scar tissue, lymphedema, chronic inflammation, severe muscle contractures, joint stiffness and capsulitis, tendinosis, tissue fibrosis and keloids, calcifications

Source: Unibell Srl, Human Tecar HCR 1002 training material (2017) and humantecar.com product page. Indication-based power values ​​are not publicly disclosed by the manufacturer: the therapist doses according to the patient's sensation and the parameters visible on the screen, this is taught in the Human Tecar training. The recommendations in the table do not replace the assessment of a doctor or physiotherapist. In case of persistent or acute complaints, consult a specialist.

Treatment structure

  1. Evaluation. The therapist determines the treatment goal: acute or chronic problem, pain and inflammation, swelling or effusion, restoration of function.
  2. Treatment planning. The duration of the entire session is, according to the manufacturer's examples, 30 minutes, 1 hour, or 1,5 hours, depending on the patient's position and the type of treatment.
  3. Body preparation. Preparatory massage with functional products.
  4. RES mode. Work with connective tissue and bone tissue.
  5. CAP mode. Revitalization and drainage of hypotrophic muscles.
  6. Final phase. Restoring balance, restorative bandages or creams if necessary.
Four stages of the Human Tecar sample treatment: body preparation, resistive mode, capacitive mode, and final phase
Manufacturer's sample treatment sequence: preparation, RES mode (connective and bone tissue), CAP mode (muscle and drainage), final phase. Source: Unibell, Human Tecar HCR 1002 training material.

During the treatment, the therapist continuously moves the active electrode over the area being treated. The electrolytic emulsion reduces skin resistance, allows the electrode to move smoothly, and helps prevent the effect from being concentrated only in the superficial tissues. No treatment is performed without the emulsion.

Human Tecar in practice: Magnus Kirt

Video (YouTube)

When you open a video, Google receives your IP address. Always allow

Medpoint's video shows how the Human Tecar treatment prepares javelin thrower Magnus Kirti's muscles for competition: the therapist combines the use of the device with manual massage.

Safety and contraindications

The HCR 1002 is a non-invasive device that is used only on intact skin. The device is used by a trained healthcare professional.

Do not use without the permission of your doctor., if the patient has a pacemaker or other active implant, if the patient is pregnant, if there is a tumor, thrombophlebitis, open wound or skin damage in the treatment area, if the patient has a blood clotting disorder or impaired temperature sensitivity. The eye and mucous membrane area is not treated. A complete list of contraindications is provided in the device instructions for use.

Technical specifications

Brand Unibell Srl, Italy (brand Human Tecar®)
Technology TECAR: Capacitive (CAP) and Resistive (RES) Energy Transfer
Operating frequency 0,447 MHz (447,000 Hz)
Power RES 300 W, CAP 450 VA
Screen Color display: mode, timer, power (%), output power, voltage, current and tissue resistance
Management Device panel and wireless remote control
CAP electrodes Flat thermodynamic Ø 80/65/55/40/30 mm, convex thermodynamic Ø 65/55/40/30 mm, convex lymphodynamic Ø 55/40 mm
RES electrodes Flat, stainless steel, Ø 90/65/50/35 mm
Handheld devices Ergonomic Smart Use handpieces for quick electrode changes
Neutral electrode Flat plate and cylindrical electrode
Weight approximately 7,5 kg

Warranty and training

  • 2-year warranty, warranty repairs are performed by Medpoint in Estonia
  • The device comes with free, comprehensive user training
  • We will confirm the exact set composition (electrodes, hand devices, emulsion) in the offer.

Comparison: which TECAR device to choose?

Product Frequency Power Who is it suitable for?
Human Tecar HCR 1002 (this product) 0,447 MHz RES 300 W / CAP 450 VA Clinic and top sports that want the Human Tecar methodology with training
HUMAN TECAR HCR1002 rental 0,447 MHz same device For a trial, short-term project or competition period
Easytech T CaRe – Diathermy Model PLUS set 4 frequencies: 420/500/720/1000 kHz up to 300 W Clinician who wants to choose between multiple frequencies for different depths
WINBACK TecarTherapy BACK 3SE therapy device 300kHz, 500kHz, 1MHz CET 300 VA / RET 100 W Clinic working according to the Winback methodology, device on a trolley
Winback Back3 TX TecarTherapy therapy device 300/500/1000kHz 100 W TECAR with Hi-TENS and Hi-EMS current types in one device

View all TECAR therapy products

Suitable accessories

Human Tecar HCR 1002 is a professional medical device. Medpoint is the official representative of Human Tecar in Estonia: we help with device selection, organize training and perform warranty repairs. If you want to try the device before buying, you can also rent it.

Additional information
Weight20.000 kg
Reviews (0)

Reviews

There are no product reviews yet.

Be the first to review “HUMAN TECAR HCR1002 TECAR Therapy Flagship”
Delivery methods and prices
📦
Parcel machines
Omniva parcel machine
€2.29
A dream of a parcel machine
€2.05
Venipak parcel machine
€2.17
DPD parcel machine
€3.10
SmartPost parcel terminal
€2.03
🚗
Courier services
Omniva kuller
€6.84
Venipak courier
€6.45
DPD courier
€9.92
SmartPost courier
€6.20
Courier for special-sized goods
€37.20
(I.e.
Other services
Omniva post office
€2.02
Transport by pallet
€27.28
📍
I'll pick you up myself
Lasnamäe: Tähesaju 11-11, Tallinn
FOR FREE
City center: Orphanage 31, Tallinn
FOR FREE

💡 Good to know: This information is valid within Estonia. The price of international deliveries depends on the product and destination.
The delivery time is indicated on the product. The delivery time is valid in 99% of cases. It may happen that the delivery is delayed.
for various reasons. Which will be notified immediately in any case.
Orders over €50 - FREE parcel terminal!

Installment payment